Contator de 4 polos adequado para aplicações de distribuição e ferrovias com comutação CA e CC. Operado com tensão de controle, versões de 24 a 690 CA, 50/60 Hz e 24 a 220 V CC.
Ordering
Quantidade Mínima de Encomenda:
1 piece
Número de tarifa aduaneira:
85364900
Dimensions
Largura Líquida do Produto:
270 mm
Profundidade/Comprimento Líquidos do Produto:
225.5 mm
Altura Líquida do Produto:
272 mm
Peso Líquido do Produto:
15.5 kg
Technical
Number of Main Contacts NO:
4
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Número de polos:
4P
Tensão operacional nominal:
Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 800 A
Rated Operational Current AC-1 (Ie):
(1000 V) 40 °C 800 A
(1000 V) 60 °C 650 A
(1000 V) 70 °C 575 A
(690 V) 40 °C 800 A
(690 V) 55 °C 650 A
(690 V) 60 °C 650 A
(690 V) 70 °C 575 A
Rated Operational Current AC-3 (Ie):
(440 V) 55 °C 550 A
(500 V) 55 °C 550 A
(690 V) 55 °C 550 A
(1000 V) 55 °C 175 A
(380 / 400 V) 55 °C 550 A
(220 / 230 / 240 V) 55 °C 550 A
Rated Operational Power AC-3 (Pe):
(415 V) 315 kW
(440 V) 315 kW
(500 V) 400 kW
(690 V) 500 kW
(1000 V) 35 kW
(380 / 400 V) 280 kW
(220 / 230 / 240 V) 160 kW
Rated Breaking Capacity AC-3:
8 x Ie AC-3
Rated Making Capacity AC-3:
10 x Ie AC-3
Dispositivos com proteção de curto-circuito:
gG Type Fuses 1.5 ... 1.8 In A
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 5300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 5500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3700 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 120 cycles per hour
(AC-3) 300 cycles per hour
Mechanical Durability:
5 million
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Coil Operating Limits:
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc):
50 Hz 230 ... 240 V
Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 125 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 140 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 3500 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 4000 V·A
Power Loss:
at Rated Operating Conditions per Pole 60 W
Operate Time:
Between Coil De-energization and NC Contact Closing 10 ... 20 ms
Between Coil De-energization and NO Contact Opening 13 ... 23 ms
Between Coil Energization and NC Contact Opening 25 ... 55 ms
Between Coil Energization and NO Contact Closing 30 ... 60 ms
Grau de proteção:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Connecting Terminals (delivered in open position) Main Poles:
Flat type c/w screws and bolts
Tipo de terminal:
Main Circuit: Bars
Nome de Produto:
Block Contactor
Technical UL/CSA
General Use Rating UL/CSA:
(600 V AC) 540 A
Environmental
Temperatura do ar ambiente:
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -50 ... 70 °C
Altitude de operação máxima permissível:
Without Derating 3000 m
Container Information
Unidades de embalagem Nível 1:
box 1 piece
Largura da embalagem Nível 1:
317 mm
Profundidade/Comprimento da embalagem Nível 1:
373 mm
Altura da embalagem Nível 1:
234 mm
Peso bruto da embalagem Nível 1:
17.2 kg
Nível de Embalagem 1 EAN:
7320500006955